| Back to Model 2001A | ||||||||
|
||||||||
| OUTPUT · Two outputs: Function out, TTL-DC coupled, BNC Connector FUNCTION OUTPUT · Impedance: 600 ohm, ±5% short circuit protected. · Amplitude: 4 selectable ranges - 1mV to 10mV p-p, 10 mV to 100mV p-p, 100mV to 1V p-p,1V to 10Vp-p (open circuit) · DC Offset Zero when feature not selected, variable -5V DC to +5V DC into open circuit when selected; total AC (signal) plus DC (offset) output limited to ±10V p-p open circuit ±5V p-p into 600 ohms. FUNCTION OUTPUT · Drive Standard TTL-level square wave (in all modes), buffered to drive 10 TTL loads, rise/fall time less than 25nsec, synchronous with Function outputs. SWEEP INPUT · Sweep Input: DC coupled, BNC Connector · Impedance: 30 Kohms · Sensitivity: 0 to ±10V input sums with voltage at frequency vernier to sweep output frequency to 100:1; linear sweep range 10:1, max in ±12V. MODES · Frequency Range: 0.2Hz to 200KHz set with a continuously variable 10:1 frequency vernier, marked in 45 divisions and 6 decade ranges, calibrate to ±5% of setting at 10Hz, 100Hz, 1kHz, 10kHz. · Square: ±1% typical time symmetry square wave (calibrated to <1.5% with rise/fall time less than 100nsec (into 600 ohms +20pF). · Triangle Linearity: Better than 1% · Sine: + distortion<1% typical; calibrated to <2% up to 100kHz. CONTROLS · Frequency: 6 range decade selectors, Level 4 range decade selectors, Sine/square/triangle mode selectors, Frequency vernier dial, Variable offset level, Variable amplitude. POWER · Power120V AC, 60 Hz or 220V AC 50 Hz switchable. GENERAL · Size: 245 (W) x 76 (H) x 185 (D) approx. · Weight: 4 lbs. · Environmental Operating Range: 0-50šC, (calibrated at 25šC ±5) |